53
Compatibility between PASO Microphone/Consoles and Amplifiers
MODEL
B701-MG
B711-G
B711/6 -G
PMB106-G
PMB112-G
B53-C
Characteristics
Dynamic microphone, general call push-button (PTT),
automatic release or one switch type (LOCK)
Electret microphone, general call push-button (PTT),
automatic release or one switch type (LOCK), dynamics compressor
Dynamic microphone, general call push-
button (PTT), dynamics compressor
Zone selection
1
6 + ALL
12 + ALL
1
Sensitivity / Impedance
1,8 mV/Pa / 500 Ω
Trimmer adjustment
Keyboard adjustment
Trimmer adjustment
frequency response
100 ÷ 12.000 Hz
100 ÷ 15.000 Hz
100 ÷ 14.000 Hz
50 ÷ 14.000 Hz
Output audio level
-
1,2 Vrms (balanced)
2,2 V max
2 V RMS (unbalanced)
Connections
5 m cable with XLR plug e 2 terminals
for activacting microphone precedence
RJ45 (AUDIO OUT) RJ45 (AUDIO OUT
e ZONE 1÷6)
RJ45 (IN/OUT)
Solder wires
Mains power supply
12 Vdc (precedence)
12 / 24 Vdc
18 /36 Vdc
11÷28 Vdc
Consumption
LED 8 mA (12 V)
45 mA
60 mA
16 mA
22 mA
30 mA
Finish
Light grey ABS structure
Black metal
Dimensions (W x H x D)
116 x 440 x 200 mm
116 x 416 x 200 mm
47 x 454 x 188 mm
Weight
0,88 kg
0,8 kg
0,6 kg
0,8 kg
Accessories
AC700
fixing mounting kit for B700 and PMB microphone station range
-
B701-MG
B711-G
B711/6-G
PMB106-G
PMB112-G
B53-C
MODEL
M1-NC M936 MC102 MC250
B701-MG
B53-C
B711-G
B711/6-G
PMB106-G
M976
MC260 MC265
PMB112-G
Type
Dynamic
microphone
Electret microphone
(Phantom
power supply)
Base with dynamic
microphone
(+12 V precedence)
Pre-amplified base with
dynamic microphone
(+12 V precedence)
Pre-amplified base (+12 V precedence)
Pre-amplified base
(RS485 serial data)
Connection
XLR
XLR + 2 precedence wires
Wires
RJ45 sockets (SFTP CAT 5 shielded cables and shielded connectors)
Functionality
Mixing
Mixing or with priority if
connecting precedence
With priority
With priority and zone selection keys
Compatibility with audio inputs of PASO amplifier/control units
AX3504
MIC 2
MIC 2 + Precedence
TEL/EMERG + Precedence (wires connection)
-
-
AX3506, AX3512
MIC 1÷4
MIC 1÷4 + Precedence
TEL/EMERG + Precedence
(wires connection)
IN UNITS
-
-
AX6000 range
MIC 1÷5
MIC 1÷5 + Precedence
TEL/EMERG + Precedence (wires connection)
-
IN UNITS
PA6000 range
MIC 1÷5
MIC 1÷5 + Precedence
TEL/EMERG + Precedence (wires connection)
-
IN UNITS
PA1000 range
MIC 1÷3
MIC 1÷3 + Precedence
MIC 1÷3 + Precedence (wires connection and XLR)
-
-
AW5600 range
-
-
-
TEL/EMERG + Precedence
(wires connection)
IN UNITS
-
-
MX5539
MIC 2÷9
MIC 2÷9
(no precedence)
-
-
-
-
P8036
-
-
-
BASE IN with precedence
(wires connection)
BASE IN with prec. + ZONE
(wires connection)
-
P8136
-
-
-
Using ACIO8136 module (wires connection)
MASTER UNITS
and LOCAL UNITS
P8236
-
-
-
Using ACIO8136 module (wires connection)
LOCAL UNITS
Connection accessories
Extension cables
CV15, CV24
CV15, CV24
+ 2 wires for precedence
-
CV20xx cable range
Cable rolls
31/2-100
31/84-100
31/65-250
31/142-100